<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sun/Oracle &#8211; Parallel Suntech, Inc.</title>
	<atom:link href="https://parallelsuntech.com/product-category/server-hardware/sun-oracle/feed/" rel="self" type="application/rss+xml" />
	<link>https://parallelsuntech.com</link>
	<description></description>
	<lastBuildDate>Tue, 04 Jun 2019 18:10:23 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.3</generator>
	<item>
		<title>Enterprise T5440</title>
		<link>https://parallelsuntech.com/product/enterprise-t5440/</link>
					<comments>https://parallelsuntech.com/product/enterprise-t5440/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Tue, 04 Jun 2019 18:09:36 +0000</pubDate>
				<guid isPermaLink="false">http://www.rogolcreative.com/solar_systems/?post_type=product&#038;p=267</guid>

					<description><![CDATA[Introduced in October of 2008, the Sun Enterprise T5440 Server is the most powerful &#8211; and only scalable &#8211; of Sun&#8217;s line of Coolthreads® servers, which also includes the Sun Fire T1000, the Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5220, and the Sun Enterprise T5240 servers. They&#8217;re [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Introduced in October of 2008, the Sun Enterprise T5440 Server is the most powerful &#8211; and only scalable &#8211; of Sun&#8217;s line of Coolthreads® servers, which also includes the Sun Fire T1000, the Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5220, and the Sun Enterprise T5240 servers. They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other server manufacturers.</p>
<p>At the time of its product announcement, the Sun Enterprise T5440 was billed as the “World’s first quad-socket, general-purpose server powered by the UltraSPARC T2 Plus &#8220;system on a chip&#8221; processor.</p>
<p>The Sun Enterprise T5440 server provides the flexibility and power of 256 virtual systems in a single server, and more than 2,500 compute threads per rack.</p>
<p>Other features of the T5440 include: One to four CPUs that are 8 core 1.2 GHz, 1.4 GHz, or 1.6 GHz UltraSPARC T2 plus processors; up to 512 GB of memory using 8 GB DIMMs; up to 4 ea. 300 GB SAS disk drives or 32 GB 2.5-Inch SATA SSDs (solid state drives), integrated on-chip cryptographic acceleration and on-board 10-gigabit Ethernet for secure computing and high-speed networking.</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">CPU</td>
<td class="text" align="center" width="95">2 x 8-Core UltraSPARC T2 Plus, 1.2 GHz, 128 Threads</td>
<td class="text" align="center" width="95">4 x 8-Core UltraSPARC T2 Plus, 1.2 GHz, 128 Threads</td>
<td class="text" align="center" width="95">4 x 8-Core UltraSPARC T2 Plus, 1.4 GHz, 128 Threads</td>
</tr>
<tr>
<td class="configs">Cache</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">16 GB (8 x 2 GB DIMM)</td>
<td class="text" align="center" width="95">64 GB (16 x 4 GB DIMM)</td>
<td class="text" align="center" width="95">128 GB (64 x 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">Network</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports and 2 × 10 Gbps Ethernet ports via the two XAUI slots</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports and 2 × 10 Gbps Ethernet ports via the two XAUI slots</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports and 2 × 10 Gbps Ethernet ports via the two XAUI slots</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Network Management</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
</tr>
<tr>
<td class="configs">Serial Management</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Serial</td>
<td class="text" align="center" width="95">One DB-9 serial port connector</td>
<td class="text" align="center" width="95">One DB-9 serial port connector</td>
<td class="text" align="center" width="95">One DB-9 serial port connector</td>
</tr>
<tr>
<td class="configs">SAS</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E 8-port, 3.0 Gbit/sec. SAS/SATA Controller</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E 8-port, 3.0 Gbit/sec. SAS/SATA Controller</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E 8-port, 3.0 Gbit/sec. SAS/SATA Controller</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Remote Management</td>
<td class="text" align="center" width="95">System controller running ILOM (Integrated Lights Out Manager) software with one 10/100 Mbps Ethernet network management port and one DB-9 serial port</td>
<td class="text" align="center" width="95">System controller running ILOM (Integrated Lights Out Manager) software with one 10/100 Mbps Ethernet network management port and one DB-9 serial port</td>
<td class="text" align="center" width="95">System controller running ILOM (Integrated Lights Out Manager) software with one 10/100 Mbps Ethernet network management port and one DB-9 serial port</td>
</tr>
<tr>
<td class="configs">USB</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">PCI Expansion Slots</td>
<td class="text" align="center" width="95">8 low-profile, 8-lane PCI-Express slots</td>
<td class="text" align="center" width="95">8 low-profile, 8-lane PCI-Express slots</td>
<td class="text" align="center" width="95">8 low-profile, 8-lane PCI-Express slots</td>
</tr>
<tr>
<td class="configs">Disk Drive</td>
<td class="text" align="center" width="95">2 x 73 GB 10K RPM SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 146 GB 10K RPM SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 300 GB 10K RPM SAS 2.5&#8243; drive</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Removable Media</td>
<td class="text" align="center" width="95">One slimline slot-loaded DVD-R/W</td>
<td class="text" align="center" width="95">One slimline slot-loaded DVD-R/W</td>
<td class="text" align="center" width="95">One slimline slot-loaded DVD-R/W</td>
</tr>
<tr>
<td class="configs">Power Supply</td>
<td class="text" align="center" width="95">4 × 1,133 Watt, hot-swappable, 2 + 2 redundant power supply units</td>
<td class="text" align="center" width="95">4 × 1,133 Watt, hot-swappable, 2 + 2 redundant power supply units</td>
<td class="text" align="center" width="95">4 × 1,133 Watt, hot-swappable, 2 + 2 redundant power supply units</td>
</tr>
<tr>
<td align="right"><span><strong><em>Solar Price</em></strong></span></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/enterprise-t5440/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Enterprise T5240</title>
		<link>https://parallelsuntech.com/product/enterprise-t5240/</link>
					<comments>https://parallelsuntech.com/product/enterprise-t5240/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Tue, 04 Jun 2019 18:08:02 +0000</pubDate>
				<guid isPermaLink="false">http://www.rogolcreative.com/solar_systems/?post_type=product&#038;p=265</guid>

					<description><![CDATA[Introduced in April of 2008, the Sun Enterprise T5240 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000, the Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5220, and the Sun Enterprise T5440 servers. They&#8217;re named Coolthreads® both because of their chip multithreading [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Introduced in April of 2008, the Sun Enterprise T5240 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000, the Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5220, and the Sun Enterprise T5440 servers. They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other server manufacturers.</p>
<p>At the time of its product announcement, the Sun Enterprise T5240 was billed as “the World&#8217;s first dual-socket, general-purpose CMT server powered by the 3rd generation UltraSPARC T2 Plus processor.”</p>
<p>The Sun Enterprise T5240 server provides the flexibility and power of 128 virtual systems in a single server, and 2,500 compute threads per rack.</p>
<p>Other features of the T5240 include: CPUs that are 4, 6, or 8 core 1.2 GHz, 8 core 1.4 GHz, or 8 core 1.6 GHz UltraSPARC T2 plus processors; up to 256 GB of memory using 8 GB DIMMs; up to 16 ea. 300 GB SAS disk drives or 32 GB 2.5-Inch SATA SSDs (solid state drives), integrated on-chip cryptographic acceleration and on-board 10-gigabit Ethernet for secure computing and high-speed networking.</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">CPU</td>
<td class="text" align="center" width="95">2 x 4-Core UltraSPARC T2 Plus, 1.2 GHz, 64 Threads</td>
<td class="text" align="center" width="95">2 x 6-Core UltraSPARC T2 Plus, 1.2 GHz, 96 Threads</td>
<td class="text" align="center" width="95">2 x 8-Core UltraSPARC T2, 1.2 GHz, 128 Threads</td>
</tr>
<tr>
<td class="configs">Cache</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">16 GB (16 x 1 GB DIMM)</td>
<td class="text" align="center" width="95">32 GB (16 x 2 GB DIMM)</td>
<td class="text" align="center" width="95">64 GB (16 x 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">Network</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Network Management</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
</tr>
<tr>
<td class="configs">Serial Management</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Serial</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
</tr>
<tr>
<td class="configs">Remote Management</td>
<td class="text" align="center" width="95">Onboard system controller running Integrated Lights Out Manager (ILOM) 2.0 with two command sets &#8211; ILOM and ALOM CMT compatibility shell, both available through the RJ-45 serial and 10/100Mbps ethernet interfaces</td>
<td class="text" align="center" width="95">Onboard system controller running Integrated Lights Out Manager (ILOM) 2.0 with two command sets &#8211; ILOM and ALOM CMT compatibility shell, both available through the RJ-45 serial and 10/100Mbps ethernet interfaces</td>
<td class="text" align="center" width="95">Onboard system controller running Integrated Lights Out Manager (ILOM) 2.0 with two command sets &#8211; ILOM and ALOM CMT compatibility shell, both available through the RJ-45 serial and 10/100Mbps ethernet interfaces</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">USB</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
</tr>
<tr>
<td class="configs">PCI Expansion Slots</td>
<td class="text" align="center" width="95">4 dedicated eight-lane PCIe expansion slots and 2 eight-lane PCIe or XAUI expansion slots</td>
<td class="text" align="center" width="95">4 dedicated eight-lane PCIe expansion slots and 2 eight-lane PCIe or XAUI expansion slots</td>
<td class="text" align="center" width="95">4 dedicated eight-lane PCIe expansion slots and 2 eight-lane PCIe or XAUI expansion slots</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Disk Drive</td>
<td class="text" align="center" width="95">2 x 73 GB 10K RPM SAS 2.5</td>
<td class="text" align="center" width="95">2 x 146 GB 10K RPM SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 300 GB 10K RPM SAS 2.5&#8243; drive</td>
</tr>
<tr>
<td class="configs">Removable Media</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Power Supply</td>
<td class="text" align="center" width="95">2 × 1100 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 1100 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 1100 Watt, hot-swappable, N+1 redundant power supply units</td>
</tr>
<tr>
<td align="right"><strong><em>Solar Price</em></strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/enterprise-t5240/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Enterprise T5220</title>
		<link>https://parallelsuntech.com/product/enterprise-t5220/</link>
					<comments>https://parallelsuntech.com/product/enterprise-t5220/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Tue, 04 Jun 2019 18:06:05 +0000</pubDate>
				<guid isPermaLink="false">http://www.rogolcreative.com/solar_systems/?post_type=product&#038;p=263</guid>

					<description><![CDATA[The Sun Enterprise T5220 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000 the Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers.. They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The Sun Enterprise T5220 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000 the Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers.. They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other server manufacturers.</p>
<p>When it was introduced in November of 2007, the Sun Enterprise T5220 was billed as “the world&#8217;s ultimate virtualization server” because it was the fastest server designed for virtualization at the time of its debut. The Sun Fire T5220 server provides the flexibility and power of 64 virtual systems in a single server, giving maximum energy efficiency, with the industry&#8217;s best performance per watt.</p>
<p>Other features of the T5220 include: CPUs that are 4, 6, or 8 core 1.2 GHz, 8 core 1.4 GHz, or 8 core 1.6 GHz UltraSPARC T2 processors with one processor per system and a maximum of 64 threads; up to 128 GB of memory using 8 GB DIMMs; and up to 16 ea. 300 GB SAS disk drives or 32 GB 2.5-Inch SATA SSDs (solid state drives).</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">CPU</td>
<td class="text" align="center" width="95">1 x 4-Core UltraSPARC T2, 1.2 GHz, 32 Threads</td>
<td class="text" align="center" width="95">1 x 8-Core UltraSPARC T2, 1.2 GHz, 64 Threads</td>
<td class="text" align="center" width="95">1 x 8-Core UltraSPARC T2, 1.4 GHz, 64 Threads</td>
</tr>
<tr>
<td class="configs">Cache</td>
<td class="text" align="center" width="95">4MB Level 2</td>
<td class="text" align="center" width="95">4MB Level 2</td>
<td class="text" align="center" width="95">4MB Level 2</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">16 GB (16 x 1 GB DIMM)</td>
<td class="text" align="center" width="95">32 GB (16 x 2 GB DIMM)</td>
<td class="text" align="center" width="95">64 GB (16 x 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">Network</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Network Management</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
</tr>
<tr>
<td class="configs">Serial Management</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Serial</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
</tr>
<tr>
<td class="configs">SAS/SATA Controller</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">USB</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
</tr>
<tr>
<td class="configs">PCI Expansion Slots</td>
<td class="text" align="center" width="95">6 low-profile PCI-Express slots; slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
<td class="text" align="center" width="95">6 low-profile PCI-Express slots; slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
<td class="text" align="center" width="95">6 low-profile PCI-Express slots; slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Disk Drive</td>
<td class="text" align="center" width="95">2 x 73 GB SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">4 x 146 GB SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">4 x 300 GB SAS 2.5&#8243; drive</td>
</tr>
<tr>
<td class="configs">Removable Media</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Power Supply</td>
<td class="text" align="center" width="95">2 × 750 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 750 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 750 Watt, hot-swappable, N+1 redundant power supply units</td>
</tr>
<tr>
<td align="right"><span><strong><em>Solar Price</em></strong></span></td>
<td align="center"><strong> $2,155 </strong></td>
<td align="center"><strong> $3,225 </strong></td>
<td align="center"><strong> $6,935</strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/enterprise-t5220/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Enterprise T5140</title>
		<link>https://parallelsuntech.com/product/enterprise-t5140/</link>
					<comments>https://parallelsuntech.com/product/enterprise-t5140/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Tue, 04 Jun 2019 18:04:44 +0000</pubDate>
				<guid isPermaLink="false">http://www.rogolcreative.com/solar_systems/?post_type=product&#038;p=261</guid>

					<description><![CDATA[Introduced in April of 2008, the Sun Enterprise T5140 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000, Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5220, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers. They&#8217;re named Coolthreads® both because of their chip multithreading technology [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Introduced in April of 2008, the Sun Enterprise T5140 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000, Sun Fire T2000, the Sun Enterprise T5120, the Sun Enterprise T5220, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers. They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other server manufacturers.</p>
<p>At the time of its product announcement, the Sun Enterprise T5140 was billed as “the World&#8217;s first dual-socket, general-purpose CMT server powered by the 3rd generation UltraSPARC T2 Plus processor.”</p>
<p>Only configured with two CPUs, the Sun Enterprise T5140 server provides the flexibility and power of 128 virtual systems in a single server, and 5,120 compute threads per rack.</p>
<p>Other features of the T5140 include: CPUs that are 4, 6, or 8 core 1.2 GHz, 8 core 1.4 GHz, or 8 core 1.6 GHz UltraSPARC T2 processors; up to 128 GB of memory using 8 GB DIMMs; up to 4 ea. 300 GB SAS disk drives or 32 GB 2.5-Inch SATA SSDs (solid state drives), integrated on-chip cryptographic acceleration and on-board 10-gigabit Ethernet for secure computing and high-speed networking.</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">CPU</td>
<td class="text" align="center" width="95">2 x 4-Core UltraSPARC T2 Plus, 1.2 GHz, 64 Threads</td>
<td class="text" align="center" width="95">2 x 6-Core UltraSPARC T2 Plus, 1.2 GHz, 96 Threads</td>
<td class="text" align="center" width="95">2 x 8-Core UltraSPARC T2, 1.2 GHz, 128 Threads</td>
</tr>
<tr>
<td class="configs">Cache</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
<td class="text" align="center" width="95">4MB Level 2 cache per processor</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">16 GB (16 x 1 GB DIMM)</td>
<td class="text" align="center" width="95">32 GB (16 x 2 GB DIMM)</td>
<td class="text" align="center" width="95">64 GB (16 x 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">Network</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Network Management</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
</tr>
<tr>
<td class="configs">Serial Management</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Serial</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
</tr>
<tr>
<td class="configs">Remote Management</td>
<td class="text" align="center" width="95">Onboard system controller running Integrated Lights Out Manager (ILOM) 2.0 with two command sets &#8211; ILOM and ALOM CMT compatibility shell, both available through the RJ-45 serial and 10/100Mbps ethernet interfaces</td>
<td class="text" align="center" width="95">Onboard system controller running Integrated Lights Out Manager (ILOM) 2.0 with two command sets &#8211; ILOM and ALOM CMT compatibility shell, both available through the RJ-45 serial and 10/100Mbps ethernet interfaces</td>
<td class="text" align="center" width="95">Onboard system controller running Integrated Lights Out Manager (ILOM) 2.0 with two command sets &#8211; ILOM and ALOM CMT compatibility shell, both available through the RJ-45 serial and 10/100Mbps ethernet interfaces.</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">USB</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
</tr>
<tr>
<td class="configs">PCI Expansion Slots</td>
<td class="text" align="center" width="95">3 low-profile PCI-Express slots with slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
<td class="text" align="center" width="95">3 low-profile PCI-Express slots with slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
<td class="text" align="center" width="95">3 low-profile PCI-Express slots with slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Disk Drive</td>
<td class="text" align="center" width="95">2 x 73 GB 10K RPM SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 146 GB 10K RPM SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 300 GB 10K RPM SAS 2.5&#8243; drive</td>
</tr>
<tr>
<td class="configs">Removable Media</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Power Supply</td>
<td class="text" align="center" width="95">2 × 720 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 720 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 720 Watt, hot-swappable, N+1 redundant power supply units</td>
</tr>
<tr>
<td align="right"><span><strong><em>Solar Price</em></strong></span></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
<td align="center"><strong> <span style="color: red;">CALL</span> </strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/enterprise-t5140/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Enterprise T5120</title>
		<link>https://parallelsuntech.com/product/enterprise-t5120/</link>
					<comments>https://parallelsuntech.com/product/enterprise-t5120/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Tue, 04 Jun 2019 18:01:30 +0000</pubDate>
				<guid isPermaLink="false">http://www.rogolcreative.com/solar_systems/?post_type=product&#038;p=258</guid>

					<description><![CDATA[The Sun Enterprise T5120 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000, the Sun Fire T2000, the Sun Enterprise T5140, the Sun Enterprise T5220, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers. They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The Sun Enterprise T5120 Server is part of Sun&#8217;s line of Coolthreads® servers, along with the Sun Fire T1000, the Sun Fire T2000, the Sun Enterprise T5140, the Sun Enterprise T5220, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers.</p>
<p>They&#8217;re named Coolthreads® both because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other server manufacturers.</p>
<p>When it was introduced in November of 2007, the Sun Enterprise T5120 was billed as “the world&#8217;s ultimate virtualization server” because it was the fastest server designed for virtualization at the time of its debut. Like the Sun Enterprise T5220, the Sun Enterprise T5120 server provides the flexibility and power of 64 virtual systems in a single server, giving maximum energy efficiency, with the industry&#8217;s best performance per watt.</p>
<p>Other features of the T5120 include: UltraSPARC T2 processor technology with CPUs that are 4, 6, or 8 core 1.2 GHz, 8 core 1.4 GHz, or 8 core 1.6 GHz UltraSPARC T2 processors with one processor per system and a maximum of 64 threads; up to 128 GB of memory using 8 GB DIMMs; and up to 8 ea. 300 GB SAS disk drives or 32 GB 2.5-Inch SATA SSDs (solid state drives).</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">CPU</td>
<td class="text" align="center" width="95">1 x 4-Core UltraSPARC T2, 1.2 GHz, 32 Threads</td>
<td class="text" align="center" width="95">1 x 8-Core UltraSPARC T2, 1.2 GHz, 64 Threads</td>
<td class="text" align="center" width="95">1 x 8-Core UltraSPARC T2, 1.4 GHz, 64 Threads</td>
</tr>
<tr>
<td class="configs">Cache</td>
<td class="text" align="center" width="95">4MB Level 2</td>
<td class="text" align="center" width="95">4MB Level 2</td>
<td class="text" align="center" width="95">4MB Level 2</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">16 GB (16 x 1 GB DIMM)</td>
<td class="text" align="center" width="95">32 GB (16 x 2 GB DIMM)</td>
<td class="text" align="center" width="95">64 GB (16 x 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">Network</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
<td class="text" align="center" width="95">4 × 10/100/1000 Mbps ports</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Network Management</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T RJ-45 port Ethernet port</td>
</tr>
<tr>
<td class="configs">Serial Management</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
<td class="text" align="center" width="95">One dedicated RJ-45 port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Serial</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
<td class="text" align="center" width="95">One DB-9 connector</td>
</tr>
<tr>
<td class="configs">SAS/SATA Controller</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port</td>
<td class="text" align="center" width="95">One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">USB</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
<td class="text" align="center" width="95">2 front and 2 rear USB 2.0 Ports</td>
</tr>
<tr>
<td class="configs">PCI Expansion Slots</td>
<td class="text" align="center" width="95">6 low-profile PCI-Express slots; slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
<td class="text" align="center" width="95">6 low-profile PCI-Express slots; slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
<td class="text" align="center" width="95">6 low-profile PCI-Express slots; slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Disk Drive</td>
<td class="text" align="center" width="95">2 x 73 GB SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 146 GB SAS 2.5&#8243; drive</td>
<td class="text" align="center" width="95">2 x 300 GB SAS 2.5&#8243; drive</td>
</tr>
<tr>
<td class="configs">Removable Media</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
<td class="text" align="center" width="95">Slimline DVD-Writer/CD-Writer</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Power Supply</td>
<td class="text" align="center" width="95">2 × 658 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 658 Watt, hot-swappable, N+1 redundant power supply units</td>
<td class="text" align="center" width="95">2 × 658 Watt, hot-swappable, N+1 redundant power supply units</td>
</tr>
<tr>
<td class="price" align="right"><span><strong><em>Solar Price</em></strong></span></td>
<td class="price" align="center"><strong> $2,155 </strong></td>
<td class="price" align="center"><strong> $2,675 </strong></td>
<td class="price" align="center"><strong> $6,245 </strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/enterprise-t5120/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Sun Fire T2000</title>
		<link>https://parallelsuntech.com/product/sun-fire-t1000-copy/</link>
					<comments>https://parallelsuntech.com/product/sun-fire-t1000-copy/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Tue, 04 Jun 2019 17:59:42 +0000</pubDate>
				<guid isPermaLink="false">http://www.rogolcreative.com/solar_systems/?post_type=product&#038;p=256</guid>

					<description><![CDATA[Introduced in December 2005 as a non-RoHS machine, the Sun Fire T2000 server was revised in April of 2006 to a RoHS version, and an Enterprise version May 2007, which coincided with the introduction of the Enterprise version of the Sun Fire T1000. The Sun Fire T2000 Server is part of Sun&#8217;s line of Coolthreads® [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Introduced in December 2005 as a non-RoHS machine, the Sun Fire T2000 server was revised in April of 2006 to a RoHS version, and an Enterprise version May 2007, which coincided with the introduction of the Enterprise version of the Sun Fire T1000. The Sun Fire T2000 Server is part of Sun&#8217;s line of Coolthreads® servers, so named because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other vendors. Since its introduction Sun has also introduced the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5220, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers.</p>
<p>The Sun Fire T2000 Server has set new world records for the SPECjAppServer2004. SPECjbb2005, and SPECweb2005 benchmarks, beating all other 2-way and less servers. Driven by the world&#8217;s most energy efficient processors, the Sun Fire T2000 server supports more demanding workloads in less space and energy than any other system – again – at the time of its introduction. A throughput-optimized server with up to 32 threads per processor supporting up to 64 GB RAM, the T2000 allows you to drive up utilization, drive down costs, and massively consolidate workloads with built-in, no-cost virtualization technology with Logical Domains (LDoms) and Solaris Containers.</p>
<p>The T2000 has three times the throughput at 30 percent less power and cooling costs of competitive servers.</p>
<p>The Sun Fire T2000 was EOL&#8217;d (end-of-lifed) in October 2009 and replaced with the Sun Enterprise T5120 and the Sun Enterprise T5220.</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">UltraSPARC T1 Chip Multithreaded (CMT)</td>
<td class="text" align="center" width="95">1.0 GHz 8-core</td>
<td class="text" align="center" width="95">1.2 GHz 8-core</td>
<td class="text" align="center" width="95">1.4 GHz 8-core</td>
</tr>
<tr>
<td class="configs">Cache Memory</td>
<td class="text" align="center" width="95">3 MB unified level 2 cache with ECC</td>
<td class="text" align="center" width="95">3 MB unified level 2 cache with ECC</td>
<td class="text" align="center" width="95">3 MB unified level 2 cache with ECC</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">8 GB (8 @ 1 GB DIMM)</td>
<td class="text" align="center" width="95">32 GB (16 @ 2 GB DIMM)</td>
<td class="text" align="center" width="95">64 GB (16 @ 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">10000 RPM SAS Disk Drive</td>
<td class="text" align="center" width="95">1 @ 73 GB</td>
<td class="text" align="center" width="95">2 @ 73 GB</td>
<td class="text" align="center" width="95">4 @ 146 GB</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Slimline DVD-R/CD-RW drive</td>
<td class="text" align="center" width="95">Yes</td>
<td class="text" align="center" width="95">Yes</td>
<td class="text" align="center" width="95">Yes</td>
</tr>
<tr>
<td class="configs">Power</td>
<td class="text" align="center" width="95">Two autoranging 550W (N+1), hot-swappable power supplies</td>
<td class="text" align="center" width="95">Two autoranging 550W (N+1), hot-swappable power supplies</td>
<td class="text" align="center" width="95">Two autoranging 550W (N+1), hot-swappable power supplies</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Auto-negotiating Ethernet Ports</td>
<td class="text" align="center" width="95">4 @ 10/100/1000 Mbps</td>
<td class="text" align="center" width="95">4 @ 10/100/1000 Mbps</td>
<td class="text" align="center" width="95">4 @ 10/100/1000 Mbps</td>
</tr>
<tr>
<td class="configs">Network Management</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T Ethernet port</td>
<td class="text" align="center" width="95">One dedicated 10/100Base-T Ethernet port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Remote Management (ALOM)</td>
<td class="text" align="center" width="95">SC Serial Management port and Net Management port</td>
<td class="text" align="center" width="95">SC Serial Management port and Net Management port</td>
<td class="text" align="center" width="95">SC Serial Management port and Net Management port</td>
</tr>
<tr>
<td class="configs">USB</td>
<td class="text" align="center" width="95">Front: two USB 1.1 ports; rear: two USB 1.1 ports</td>
<td class="text" align="center" width="95">Front: two USB 1.1 ports; rear: two USB 1.1 ports</td>
<td class="text" align="center" width="95">Front: two USB 1.1 ports; rear: two USB 1.1 ports</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">PCI Interfaces</td>
<td class="text" align="center" width="95">Three PCI-Express (PCI-E) low-profile, 2.5GHz lanes card slots with up to X8 data lanes; two PCI-X low-profile, 64-bit, 133 MHz card slots</td>
<td class="text" align="center" width="95">Three PCI-Express (PCI-E) low-profile, 2.5GHz lanes card slots with up to X8 data lanes; two PCI-X low-profile, 64-bit, 133 MHz card slots</td>
<td class="text" align="center" width="95">Three PCI-Express (PCI-E) low-profile, 2.5GHz lanes card slots with up to X8 data lanes; two PCI-X low-profile, 64-bit, 133 MHz card slots</td>
</tr>
<tr>
<td align="right"><strong><em>Solar Price</em></strong></td>
<td align="center"><strong> $1,030 </strong></td>
<td align="center"><strong> $1,595 </strong></td>
<td align="center"><strong> $3,710 </strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/sun-fire-t1000-copy/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Sun Fire T1000</title>
		<link>https://parallelsuntech.com/product/sun-fire-t1000/</link>
					<comments>https://parallelsuntech.com/product/sun-fire-t1000/#respond</comments>
		
		<dc:creator><![CDATA[ssp_admin]]></dc:creator>
		<pubDate>Wed, 27 Feb 2019 16:26:05 +0000</pubDate>
				<guid isPermaLink="false">http://localhost:8888/solar_systems/?post_type=product&#038;p=119</guid>

					<description><![CDATA[Originally ntroduced in March of 2006 and then in the Enterprise version in May of 2007 along with the RoHS version of the Sun Fire T2000, the Sun Fire T1000 Server is part of Sun&#8217;s line of Coolthreads® servers, so named because of their chip multithreading technology &#8211; CMT, and their low power consumption that [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Originally ntroduced in March of 2006 and then in the Enterprise version in May of 2007 along with the RoHS version of the Sun Fire T2000, the Sun Fire T1000 Server is part of Sun&#8217;s line of Coolthreads® servers, so named because of their chip multithreading technology &#8211; CMT, and their low power consumption that allows them to run &#8216;cooler&#8217; than comparable machines from other vendors. Since its introduction Sun has also introduced the Sun Enterprise T5120, the Sun Enterprise T5140, the Sun Enterprise T5220, the Sun Enterprise T5240, and the Sun Enterprise T5440 servers.</p>
<p>The Sun Fire T1000 set a new world record by delivering 51,540 BOPS for the SPECjbb2005 Benchmark, beating all other 2-way and less servers. Driven by the world&#8217;s most energy efficient processors, the Sun Fire T1000 server supports more demanding workloads in less space and energy than any other system – again – at the time of its introduction. A throughput-optimized server with up to 32 threads per processor, all in a 1U package, the T1000 delivers more than 5x the throughput per rack of Xeon-based servers running Java applications.</p>
<p>the Sun Fire T1000 and Enterprise T1000 were EOL&#8217;d (end-of-lifed) in October of 2006 and replaced with the Sun Enterprise T5120 and the Sun Enterprise T5220.</p>
<table border="0" width="100%" cellspacing="0" cellpadding="6">
<tbody>
<tr bgcolor="#FFC66C">
<td class="configs">1.0-GHz UltraSPARC T1 Chip Multithreaded (CMT)</td>
<td class="text" align="center" width="95">One 6-Core UltraSPARC T1</td>
<td class="text" align="center" width="95">One 8-Core UltraSPARC T1</td>
<td class="text" align="center" width="95">One 8-Core UltraSPARC T1</td>
</tr>
<tr>
<td class="configs">Cache Memory</td>
<td class="text" align="center" width="95">3 MB unified level 2 cache with ECC, 16-KB primary instruction cache per core, 8-KB primary data cache per core</td>
<td class="text" align="center" width="95">3 MB unified level 2 cache with ECC, 16-KB primary instruction cache per core, 8-KB primary data cache per core</td>
<td class="text" align="center" width="95">3 MB unified level 2 cache with ECC, 16-KB primary instruction cache per core, 8-KB primary data cache per core</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Memory</td>
<td class="text" align="center" width="95">4 GB (4 @ 1 GB DIMM)</td>
<td class="text" align="center" width="95">16 GB (8 @ 2 GB DIMM)</td>
<td class="text" align="center" width="95">32 GB (8 @ 4 GB DIMM)</td>
</tr>
<tr>
<td class="configs">10000 RPM SAS Disk Drive</td>
<td class="text" align="center" width="95">1 @ 73 GB</td>
<td class="text" align="center" width="95">2 @ 73 GB</td>
<td class="text" align="center" width="95">2 @ 146 GB</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Power</td>
<td class="text" align="center" width="95">One 300W, non-redundant power supply</td>
<td class="text" align="center" width="95">One 300W, non-redundant power supply</td>
<td class="text" align="center" width="95">One 300W, non-redundant power supply</td>
</tr>
<tr>
<td class="configs">Auto-negotiating Ethernet Ports</td>
<td class="text" align="center" width="95">4 @ 10/100/1000 Mbps</td>
<td class="text" align="center" width="95">4 @ 10/100/1000 Mbps</td>
<td class="text" align="center" width="95">4 @ 10/100/1000 Mbps</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">Remote Management (ALOM)</td>
<td class="text" align="center" width="95">Two SC management ports, one RJ-45 serial management port (SERIAL MGT), one RJ-45 network management port (NET MGT)</td>
<td class="text" align="center" width="95">Two SC management ports, one RJ-45 serial management port (SERIAL MGT), one RJ-45 network management port (NET MGT)</td>
<td class="text" align="center" width="95">Two SC management ports, one RJ-45 serial management port (SERIAL MGT), one RJ-45 network management port (NET MGT)</td>
</tr>
<tr>
<td class="configs">Serial</td>
<td class="text" align="center" width="95">One DB-9 (TTYA) serial port</td>
<td class="text" align="center" width="95">One DB-9 (TTYA) serial port</td>
<td class="text" align="center" width="95">One DB-9 (TTYA) serial port</td>
</tr>
<tr bgcolor="#FFC66C">
<td class="configs">PCI Interfaces</td>
<td class="text" align="center" width="95">One PCI-Express (PCI-E) low-profile slot that supports 1x, 4x, and 8x width cards</td>
<td class="text" align="center" width="95">One PCI-Express (PCI-E) low-profile slot that supports 1x, 4x, and 8x width cards</td>
<td class="text" align="center" width="95">One PCI-Express (PCI-E) low-profile slot that supports 1x, 4x, and 8x width cards</td>
</tr>
<tr>
<td align="right"><strong><em>Solar Price</em></strong></td>
<td align="center"><strong> $1,750 </strong></td>
<td align="center"><strong> $2,015 </strong></td>
<td align="center"><strong> $2,160 </strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://parallelsuntech.com/product/sun-fire-t1000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
